Team course project (4 people)
Université de Technologie de Compiègne · BA04 Renewable Energy Conversion and Management (spring 2024)
Modelled a Kyocera KC200GT module in MATLAB/Simulink and compared P&O against the improved P&OA over 366 days of per-minute irradiance and temperature measured by UTC's STELLA platform, in terms of annual energy and efficiency.
A photovoltaic module’s I-V curve has a single maximum-power point (MPP), and its position moves continuously with irradiance and temperature. If the load pins the operating point, the module can drift far from the MPP and lose 20-30% of its production. The job of MPPT is to keep the operating point on the MPP with a DC-DC converter.
This was the BA04 “Renewable Energy Conversion and Management” course project at UTC, a team of four, defended in June 2024. The object was a Kyocera KC200GT (200 Wp polycrystalline module). We built the PV module, a SEPIC converter and the controller in Simulink, then drove the model with one full year of measurements from UTC’s STELLA platform. The report compares four algorithms: P&O, incremental conductance (INC), an improved P&O (P&OA) and fuzzy logic.
E_day = Σ P(t) · Δt / 3.6e6 [kWh]
η = Σ E_day(PV) / Σ E_day(G)
The code has three layers: loadYearData / loadDayData read the Excel files and rebuild the time axis, runSimulation / runYearSimulation run the model, and runAnalysis computes energy, efficiency, CSV files and the comparison figure. Every path is relative to the repository root, so the project can be moved freely.
In the four-person split I owned P&O and its improved version P&OA:
From Workspace blocks, one day at a timeThe other group methods (incremental conductance, fuzzy logic) are kept in archive/other_methods/; the report and defence material are in docs/.
An honest conclusion: with one-minute data over a whole year, “annual energy” smooths away the transient differences between the algorithms. A fairer comparison of P&O and P&OA uses settling time after a step, steady-state power ripple, and tracking efficiency at different step sizes.
Source, Simulink models, raw data and report: https://github.com/yicongl1/MPPT-direct